Powerfix PDM 250 A2 Manuale Utente Pagina 18

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 90
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 17
POWERFIX PDM 250 A2
16 - English
Replacing the fuse
To replace the fuse, proceed as follows:
Switch off the multimeter and remove all test leads before opening the multimeter!
Remove the holster [2].
Remove the two screws on the back of the multimeter and remove the back panel.
Replace faulty fuse F1 (F 250mA / 250V) or F2 (F 10A / 250V) with a new one of the
same type.
Replace the back panel and screw it tight with the two screws.
Re-insert the multimeter in the holster [2].